Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Adv Biochem Eng Biotechnol ; 174: 43-91, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32313965

RESUMO

Impedimetric aptamer-based biosensors show high potential for handheld devices and point-of-care tests. In this review, we report on recent advances in aptamer-based impedimetric biosensors for applications in biotechnology. We detail on analytes relevant in medical and environmental biotechnology as well as food control, for which aptamer-based impedimetric biosensors were developed. The reviewed biosensors are examined for their performance, including sensitivity, selectivity, response time, and real sample validation. Additionally, the benefits and challenges of impedimetric aptasensors are summarized.


Assuntos
Aptâmeros de Nucleotídeos , Técnicas Biossensoriais , Aptâmeros de Nucleotídeos/química , Técnicas Biossensoriais/normas , Técnicas Biossensoriais/tendências , Biotecnologia/tendências
2.
Adv Biochem Eng Biotechnol ; 174: 17-41, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32328684

RESUMO

Aptamers are a specific class of ligands with high affinities comparable to antibodies, which are selected and synthesized in vitro. In combination with impedance spectroscopy as sensitive measurement method, we gain a class of biosensors with high potential for handheld devices and point-of-care tests. In this review, we report on recent advances in aptamer-based impedimetric biosensors. Besides giving a short summary of electrochemical measurement techniques, the most exciting innovative developments of detection strategies in the last decades are reviewed. Finally, important criteria for the comparison of aptamer-based biosensors are discussed.


Assuntos
Aptâmeros de Nucleotídeos , Técnicas Biossensoriais , Técnicas Biossensoriais/instrumentação , Técnicas Biossensoriais/tendências , Espectroscopia Dielétrica , Técnicas Eletroquímicas/tendências
3.
Anal Bioanal Chem ; 410(5): 1453-1462, 2018 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-29199352

RESUMO

An aptamer-based biosensor was developed for the detection of doxorubicin using electrochemical impedance spectroscopy. Doxorubicin and its 14-dehydroxylated version daunorubicin are anthracyclines often used in cancer treatment. Due to their mutagenic and cardiotoxic effects, detection in groundwater is desirable. We developed a biosensor using the daunorubicin-binding aptamer as biological recognition element. The aptamer was successfully co-immobilized with mercaptohexanol on gold and a density of 1.3*1013 ± 2.4*1012 aptamer molecules per cm2 was achieved. The binding of doxorubicin to the immobilized aptamer was detected by electrochemical impedance spectroscopy. The principle is based on the inhibition of electron transfer between electrode and ferro-/ferricyanide in solution caused by the binding of doxorubicin to the immobilized aptamer. A linear relationship between the charge transfer resistance (R ct ) and the doxorubicin concentration was obtained over the range of 31 nM to 125 nM doxorubicin, with an apparent binding constant of 64 nM and a detection limit of 28 nM. With the advantages of high sensitivity, selectivity, and simple sensor construction, this method shows a high potential of impedimetric aptasensors in environmental monitoring. Graphical abstract Measurement chamber and immobilization principle for the detection of doxorubicin by electrochemical impedance spectroscopy.


Assuntos
Aptâmeros de Nucleotídeos/química , Técnicas Biossensoriais , Doxorrubicina/química , Técnicas Biossensoriais/métodos , Espectroscopia Dielétrica , Impedância Elétrica , Eletrodos , Ouro/química , Humanos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...